Switching element Switching voltage Switching current Static current Switching power Temperature Protection Connection Cable cros section |
= Reed switch with dry contact (inert gas) = Max. 48V AC/DC = Max. 50 mA = Open Contact = max. 2 W = Ambient -10.... +70°C = IP 65 (EC 144) against water-jets and dust = Cast-in cable, length 3 m = 2 x 0,14 mm2 |
![]()


|
Switching element Switching voltage Residual ripple Switching current Static current Temperature Protection Ex approval Connection
|
= Slot initator according to DIN 19234s) = 5 ... 15 V DC = max.% 5 = > 3 mA at 8 VDC / 1 kOhm = < 1 mA at 8 VDC / 1 kOhm = Ambient -10.... +70°C = IP 65 (EC 144) against water-jets and dust = EEx ia IIC T6 = Cable, min. 2 x 0,35 mm2 external diameter, on plug supplied with product. |
|
IN Pulser / VZO 15 ..... VZO 50 |
|
RV Pulser / VZO 15 ..... VZO 50 |
![]()
![]()

|
RE Pulser / VZO 4 - VZO 8 |
|
Switching element Switching voltage Switching current Static current Switching power Temperature Protection Connection |
= Reed switch with dry contact (inert gas) = Max. 48V AC/DC = Max. 50 mA = Open Contact = Max. 3 VA = Ambient -10.... +60°C = IP 65 (EC 144) against water-jets and dust = On plug supplied with product for cable,2 x 0,35 mm2 |